Startsida
Hjälp
Sök i LIBRIS databas

     

 

Sökning: onr:ftq5w5gfcsrxlz64 > Awake prone positio...

Awake prone positioning in patients with hypoxemic respiratory failure due to COVID-19 [Elektronisk resurs] the PROFLO multicenter randomized clinical trial

Rosén, Jacob (författare)
von Oelreich, Erik (författare)
Fors, Diddi (författare)
Fagerlund, Malin Jonsson (författare)
Taxbro, Knut (författare)
Skorup, Paul (författare)
Eby, Ludvig (författare)
Jalde, Francesca Campoccia (författare)
Johansson, Niclas (författare)
Bergstrom, Gustav (författare)
Frykholm, Peter, 1961- (författare)
Uppsala universitet Medicinska och farmaceutiska vetenskapsområdet (utgivare)
Uppsala universitet Medicinska och farmaceutiska vetenskapsområdet (utgivare)
Uppsala universitet Medicinska och farmaceutiska vetenskapsområdet (utgivare)
Uppsala universitet Medicinska och farmaceutiska vetenskapsområdet (utgivare)
Uppsala universitet Medicinska och farmaceutiska vetenskapsområdet (utgivare)
Publicerad: BMC, 2021
Engelska.
Ingår i: Critical Care. - 1364-8535. ; 25:1
Läs hela texten
Läs hela texten
Läs hela texten
  • E-artikel/E-kapitel
Sammanfattning Ämnesord
Stäng  
  • Background: The effect of awake prone positioning on intubation rates is not established. The aim of this trial was to investigate if a protocol for awake prone positioning reduces the rate of endotracheal intubation compared with standard care among patients with moderate to severe hypoxemic respiratory failure due to COVID-19. Methods: We conducted a multicenter randomized clinical trial. Adult patients with confirmed COVID-19, high-flow nasal oxygen or noninvasive ventilation for respiratory support and a PaO2/FiO(2) ratio <= 20 kPa were randomly assigned to a protocol targeting 16 h prone positioning per day or standard care. The primary endpoint was intubation within 30 days. Secondary endpoints included duration of awake prone positioning, 30-day mortality, ventilator-free days, hospital and intensive care unit length of stay, use of noninvasive ventilation, organ support and adverse events. The trial was terminated early due to futility. Results: Of 141 patients assessed for eligibility, 75 were randomized of whom 39 were allocated to the control group and 36 to the prone group. Within 30 days after enrollment, 13 patients (33%) were intubated in the control group versus 12 patients (33%) in the prone group (HR 1.01 (95% CI 0.46-2.21), P = 0.99). Median prone duration was 3.4 h [IQR 1.8-8.4] in the control group compared with 9.0 h per day [IQR 4.4-10.6] in the prone group (P = 0.014). Nine patients (23%) in the control group had pressure sores compared with two patients (6%) in the prone group (difference - 18% (95% CI - 2 to - 33%); P = 0.032). There were no other differences in secondary outcomes between groups. Conclusions: The implemented protocol for awake prone positioning increased duration of prone positioning, but did not reduce the rate of intubation in patients with hypoxemic respiratory failure due to COVID-19 compared to standard care. 

Ämnesord

Medical and Health Sciences  (hsv)
Clinical Medicine  (hsv)
Anesthesiology and Intensive Care  (hsv)
Medicin och hälsovetenskap  (hsv)
Klinisk medicin  (hsv)
Anestesi och intensivvård  (hsv)

Genre

government publication  (marcgt)

Indexterm och SAB-rubrik

COVID-19
Awake prone positioning
Intensive care
Critical care
Respiratory failure
High-flow nasal oxygen
Noninvasive ventilation
Intubation rates
Mechanical ventilation
Inställningar Hjälp

Ingår i annan publikation. Gå till titeln Critical Care

Om LIBRIS
Sekretess
Hjälp
Fel i posten?
Kontakt
Teknik och format
Sök utifrån
Sökrutor
Plug-ins
Bookmarklet
Anpassa
Textstorlek
Kontrast
Vyer
LIBRIS söktjänster
SwePub
Uppsök

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

Copyright © LIBRIS - Nationella bibliotekssystem

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy