Startsida
Hjälp
Sök i LIBRIS databas

     

 

Sökning: onr:cm7w7zk392d9ttgn > 4D flow MRI

4D flow MRI [Elektronisk resurs] automatic assessment of blood flow in cerebral arteries

Dunås, Tora (författare)
Wåhlin, Anders (författare)
Zarrinkoob, Laleh (författare)
Malm, Jan (författare)
Eklund, Anders (författare)
Umeå universitet Medicinska fakulteten (utgivare)
Umeå universitet Medicinska fakulteten (utgivare)
Umeå universitet Medicinska fakulteten (utgivare)
Publicerad: Institute of Physics Publishing (IOPP), 2019
Engelska.
Ingår i: ; 5:1
Läs hela texten
Läs hela texten
Läs hela texten
  • E-artikel/E-kapitel
Sammanfattning Ämnesord
Stäng  
  • Objective: With a 10-minute 4D flow MRI scan, the distribution of blood flow to individual arteries throughout the brain can be analyzed. This technique has potential to become a biomarker for treatment decisions, and to predict prognosis after stroke. To efficiently analyze and model the large dataset in clinical practice, automatization is needed. We hypothesized that identification of selected arterial regions using an atlas with a priori probability information on their spatial distribution can provide standardized measurements of blood flow in the main cerebral arteries. Approach: A new method for automatic placement of measurement locations in 4D flow MRI was developed based on an existing atlas-based method for arterial labeling, by defining specific regions of interest within the corresponding arterial atlas. The suggested method was evaluated on 38 subjects with carotid artery stenosis, by comparing measurements of blood flow rate at automatically selected locations to reference measurements at manually selected locations. Main results: Automatic and reference measurement ranged from 10 to 580 ml min −1 and were highly correlated (r = 0.99) with a mean flow difference of 0.61 ± 10.7 ml min −1 (p = 0.21). Out of the 559 arterial segments in the manual reference, 489 were correctly labeled, yielding a sensitivity of 88%, a specificity of 85%, and a labeling accuracy of 87%. Significance: This study confirms that atlas-based labeling of 4D flow MRI data is suitable for efficient flow quantification in the major cerebral arteries. The suggested method improves the feasibility of analyzing cerebral 4D flow data, and fills a gap necessary for implementation in clinical use. 

Ämnesord

Engineering and Technology  (hsv)
Medical Engineering  (hsv)
Medical Image Processing  (hsv)
Teknik och teknologier  (hsv)
Medicinteknik  (hsv)
Medicinsk bildbehandling  (hsv)

Genre

government publication  (marcgt)

Indexterm och SAB-rubrik

cerebral arteries
hemodynamics
carotid stenosis
magnetic resonance imaging
circle of willis
cerebrovascular circulation
Inställningar Hjälp

Beståndsinformation saknas

Om LIBRIS
Sekretess
Hjälp
Fel i posten?
Kontakt
Teknik och format
Sök utifrån
Sökrutor
Plug-ins
Bookmarklet
Anpassa
Textstorlek
Kontrast
Vyer
LIBRIS söktjänster
SwePub
Uppsök

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

Copyright © LIBRIS - Nationella bibliotekssystem

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy