Startsida
Hjälp
Sök i LIBRIS databas

     

 

Sökning: onr:1bjxrv4hznhsczvh > Reexamination of Ac...

Reexamination of Accelerometer Calibration with Energy Expenditure as Criterion [Elektronisk resurs] VO<sub>2net</sub> Instead of MET for Age-Equivalent Physical Activity Intensity.

Arvidsson, Daniel (författare)
Fridolfsson, Jonatan (författare)
Buck, Christoph (författare)
Ekblom, Örjan, 1971- (författare)
Ekblom Bak, Elin, 1981- (författare)
Lissner, Lauren (författare)
Hunsberger, Monica (författare)
Börjesson, Mats (författare)
Gymnastik- och idrottshögskolan, GIH Institutionen för idrotts- och hälsovetenskap (utgivare)
Publicerad: MDPI, 2019
Engelska.
Ingår i: Sensors. - 1424-8220. ; 19:15
Läs hela texten
Läs hela texten
Läs hela texten
  • E-artikel/E-kapitel
Sammanfattning Ämnesord
Stäng  
  • Accelerometer calibration for physical activity (PA) intensity is commonly performed using Metabolic Equivalent of Task (MET) as criterion. However, MET is not an age-equivalent measure of PA intensity, which limits the use of MET-calibrated accelerometers for age-related PA investigations. We investigated calibration using VO 2net (VO 2gross - VO 2stand ; mL⋅min -1 ⋅kg -1 ) as criterion compared to MET (VO 2gross /VO 2rest ) and the effect on assessment of free-living PA in children, adolescents and adults. Oxygen consumption and hip/thigh accelerometer data were collected during rest, stand and treadmill walk and run. Equivalent speed (Speed eq ) was used as indicator of the absolute speed (Speed abs ) performed with the same effort in individuals of different body size/age. The results showed that VO 2net was higher in younger age-groups for Speed abs , but was similar in the three age-groups for Speed eq . MET was lower in younger age-groups for both Speed abs and Speed eq . The same VO 2net -values respective MET-values were applied to all age-groups to develop accelerometer PA intensity cut-points. Free-living moderate-and-vigorous PA was 216, 115, 74 and 71 min/d in children, adolescents, younger and older adults with VO 2net -calibration, but 140, 83, 74 and 41 min/d with MET-calibration, respectively. In conclusion, VO 2net calibration of accelerometers may provide age-equivalent measures of PA intensity/effort for more accurate age-related investigations of PA in epidemiological research. 

Ämnesord

Medical and Health Sciences  (hsv)
Health Sciences  (hsv)
Sport and Fitness Sciences  (hsv)
Medicin och hälsovetenskap  (hsv)
Hälsovetenskaper  (hsv)
Idrottsvetenskap  (hsv)
Medicin/Teknik  (gih)
Medicine/Technology  (gih)

Genre

government publication  (marcgt)

Indexterm och SAB-rubrik

MET
VO2
VO2net
accelerometer
adolescents
adults
calibration
children
equivalent speed
free-living
physical activity
speed
Inställningar Hjälp

Beståndsinformation saknas

Om LIBRIS
Sekretess
Blogg
Hjälp
Fel i posten?
Kontakt
Teknik och format
Sök utifrån
Sökrutor
Plug-ins
Bookmarklet
Anpassa
Textstorlek
Kontrast
Vyer
LIBRIS söktjänster
SwePub
Sondera
Uppsök

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

Copyright © LIBRIS - Nationella bibliotekssystem

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy